Vaillant Fault Codes
Comprehensive reference table of all Vaillant boiler error codes. Click any code for detailed troubleshooting steps.
Pro Tip
Check your boiler's digital display panel (usually behind a drop-down cover) to find the current active fault code.
| Error Code | Description | Applies To |
|---|---|---|
F.22 | Safety switch-off: Water pressure is too low or system is entirely devoid of water. | ecoTEC Pro / Plus |
F.28 | Boiler ignition fault: Unsuccessful ignition when starting up; check gas supply. | ecoTEC Pro / Plus |
F.29 | Flame loss fault: Flame extinguishes during operation; possible gas interruption. | ecoTEC Pro / Plus |
F.75 | Pressure sensor fault: Insufficient pressure jump detected when pump starts. | ecoTEC Pro / Plus |
F.23 | Safety switch-off: Temperature spread between flow and return is too great. | ecoTEC Plus Regular |
F.24 | Safety switch-off: Temperature increased too quickly; dry fire or airlock detected. | Turbomax Plus / ecoTEC |
F.27 | False flame detection: Monitoring electrode reports an incorrect flame. | ecoTEC Pro / Plus |
F.32 | Fan fault: Fan speed outside tolerance values or fan frost protection active. | ecoTEC Plus |
F.61 | Gas valve fault: The gas valve assembly cannot be actuated electrically. | ecoTEC Pro / Plus |
F.62 | Gas valve error: Delayed switch-off sequence for the gas valve after flame is extinguished. | ecoTEC Pro / Plus |
F.00 / F.0 | Flow temperature sensor is defective, disconnected, or interrupted. | ecoTEC Pro / Plus |
F.01 / F.1 | Return temperature sensor is defective, disconnected, or interrupted. | ecoTEC Pro / Plus |
F.10 | Flow temperature sensor is defective or actively short-circuiting. | ecoTEC Pro / Plus |
F.11 | Return temperature sensor is defective or actively short-circuiting. | ecoTEC Pro / Plus |
F.20 | Safety shutdown: Maximum overheating temperature has been reached at the NTC. | ecoTEC Plus |
F.25 | Safety switch-off: The flue gas temperature is too high. | ecoTEC Plus |
F.26 | Gas valve assembly stepper motor is defective or not connected. | ecoTEC Pro |
F.49 | Undervoltage detected on the eBus communication circuit. | ecoTEC Pro / Plus |
F.63 | EEPROM is faulty; internal control board memory error. | ecoTEC Pro / Plus |
F.64 | Defect with the electronics, safety-relevant sensor, or analogue-to-digital converter. | ecoTEC Pro / Plus |
F.65 | Electronics temperature is too high; external heat source or electrical fault. | ecoTEC Plus |
F.67 | Flame signal is weak or not detected by the ASIC. | ecoTEC Plus |
F.70 | Invalid product code (Device Specific Number) or incorrect coding resistor. | ecoTEC Plus |
F.71 | Flow temperature sensor returns implausible or incorrect values. | ecoTEC Plus |
F.72 | Deviation in the water pressure sensor or return temperature sensor. | ecoTEC Plus |
F.73 | Water pressure sensor is not connected or has short-circuited. | ecoTEC Plus |
F.76 | Safety cut-out in the primary heat exchanger is defective; major overheating. | ecoTEC Plus |
F.83 | Dry fire detected; flow sensor temperature rise is too quick relative to burner output. | ecoTEC Plus |
F.84 | Permanent temperature difference between flow and return NTC thermistors. | ecoTEC Plus |
F.92 | Combustion fault; the coding resistor does not match the entered gas group. | ecoTEC Plus |
F.93 | Combustion regulation fault; gas/air mixture is outside the permitted range. | ecoTEC Plus |