Navien Error Code E016
What Does E016 Mean?
Error code E016 is a heat exchanger overheat fault - a critical safety shutdown that occurs when the heat exchanger temperature exceeds safe limits.
⚠️ This is a serious fault that requires immediate attention from a qualified engineer.
Why Overheating Occurs
Circulation Problems
- Pump failure - not circulating water through the system
- Seized pump - pump runs but impeller doesn't turn
- Airlock in the pump preventing water flow
- Closed or blocked valves restricting circulation
System Issues
- Heavy scale buildup on the heat exchanger
- Blocked pipework restricting flow
- Insufficient water volume in the system
- Faulty bypass valve not allowing flow
Component Faults
- Faulty overheat thermostat giving false readings
- PCB fault not controlling the burner properly
- Gas valve stuck open allowing continuous firing
- Faulty temperature sensors misreading temperatures
Immediate Actions
Safety First
- Turn off the boiler immediately
- Do not attempt to restart - this is a safety lockout
- Allow the boiler to cool completely (at least 30 minutes)
- Call a Gas Safe engineer - do not attempt DIY repairs
What NOT To Do
- ❌ Don't keep resetting the boiler
- ❌ Don't ignore the error
- ❌ Don't attempt to override safety features
- ❌ Don't operate the boiler if it smells hot or shows scorch marks
Why This Is Serious
Overheating can cause:
- Heat exchanger damage requiring expensive replacement
- Boiler fire risk if unchecked
- System contamination from damaged components
- Pressure relief valve activation causing leaks
- Seal and gasket failure throughout the system
What the Engineer Will Do
Diagnostic Checks
- Verify the overheat has occurred (not a sensor fault)
- Check pump operation - electrically and mechanically
- Test system circulation and flow rates
- Measure water temperature throughout the system
- Inspect heat exchanger for scale and damage
Likely Repairs
- Replace failed pump
- Flush the system to remove scale and sludge
- Replace overheat thermostat if faulty
- Repair or replace PCB
- Service or replace gas valve
- Clean or replace heat exchanger
- Add system inhibitor to prevent corrosion
Prevention
Regular Maintenance
- Annual boiler service to check all safety devices
- System flush every 5-6 years to prevent scale
- Pump check during each service
- Inhibitor levels maintained in the system
System Design
- Adequate flow rates through the boiler
- Properly sized pipework throughout
- Correct pump specification for the system
- Bypass valve correctly set
Water Quality
- Inhibitor treatment to prevent scale and corrosion
- Magnetic filter to capture debris
- Water quality checks during servicing
Applicable Models: NCB-CE, NCB300, NCB500, NCB700, LCB700, and NPE series.
Critical Note: E016 is not a fault you can ignore. Continued overheating can cause catastrophic boiler failure and potential fire risk. Always call a qualified engineer immediately when this error appears.